MLP-DRIVE INSTALLATION/START-UP GUIDE
CAUTION
Hazardous Voltages. Can cause severe injury, death or damage to
equipment. The MLP-Drive should only be installed by a qualified
electrician.
Proper earth grounding of all electronic equipment is required for
successful operation. Connect a low impedance earth ground to
terminal 5 of connector J3.
Separate all logic and signal level wiring (J1, J2, J4 and J5) from all
motor armature and AC power wiring (J3).
Shield all logic and signal wiring (J1, J2, J4 and J5) and terminate to
earth ground at one point only.
REQUIRED WIRING
CC
CC
C
ONTREX, INC.ONTREX, INC.
ONTREX, INC.ONTREX, INC.
ONTREX, INC.
SK1455 Rev 2SK1455 Rev 2
SK1455 Rev 2SK1455 Rev 2
SK1455 Rev 2
Page 1
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - REQUIRED WIRING

MLP-DRIVE INSTALLATION/START-UP GUIDECAUTIONHazardous Voltages. Can cause severe injury, death or damage toequipment. The MLP-Drive should only be in

Página 2

SCALINGAfter completing the required wiring of the MLP-Drive, follow the procedure below to scale the MLP-Drive for Masterformat RPM operation. Compl

Página 3 - TROUBLE-SHOOTING

FOLLOWER OPERATIONComplete the “Scaling” and “Tuning” procedures for Master mode (Page 2) before proceeding with Follower operation. To enable Follow

Página 4

Step 4: Check MP-47 (Drive Output).a) Should not be “0” or “100”.b) If “0”, then return to step 1 of “Scaling”.c) If “100”, check wiring to drive