CALIBRATION - SETUP RECORD
Model CXB1525/CXB2040
Brushless Servo Amplifier System
Date:
Model Number:
Serial Number:
Customer Order Number:
ENCODER
Resolution:
DIP SWITCH CONFIGURATION
Dip Switch S1 S2 S3
1 ON / OFF ON / OFF ON / OFF
2 ON / OFF ON / OFF ON / OFF
3 ON / OFF ON / OFF ON / OFF
4 ON / OFF ON / OFF ON / OFF
5 ON / OFF ON / OFF ON / OFF
6 ON / OFF ON / OFF ON / OFF
7 ON / OFF ON / OFF ON / OFF
8 ON / OFF ON / OFF ON / OFF
POTENTIOMETER SETTING
Pot Name of Pot Test Point Setting (Ohms) Notes
RV2 SIG 1 J3-A to J3-F Sets MAX speed of motor
(Signal 1)
RV3 SIG 2 J3-B to J3-F Shipped fully CCW
(Signal 2)
RV4 TACH J3-C to J3-F Sets system bandwidth
(Tach Gain)
RV5 BAL N/A Used to null any offsets in
(Balance) system
RV6 COMP J3-D to J3-F Sets system bandwidth
(Compensation)
RV7 I LIMIT J3-E to J3-F Sets Maximum motor current
(Current Limit)
RV8 LOOP N/A Shipped fully CCW
(Loop Gain) (OFF)
* To measure pot settings: RV8 must be set fully CCW and AC power must be off.
* Before making adjustments to the pot settings, please consult CONTREX Inc..
MAX RPM Vin = RPM