ML-DRIVE INSTALLATION/START-UP GUIDE
CAUTION
Hazardous Voltages. Can cause severe injury, death or damage to
equipment. The ML-Drive should only be installed by a qualified
electrician.
Proper earth grounding of all electronic equipment is required for
successful operation. Connect a low impedance earth ground to
terminal 5 of connector J2.
Separate all logic and signal level wiring (J1, J3 and J4) from all
motor armature and AC power wiring (J2).
Shield all logic and signal wiring (J1, J3 and J4) and terminate to
earth ground at one point only.
REQUIRED WIRING
CC
CC
C
ONTREX, INC.ONTREX, INC.
ONTREX, INC.ONTREX, INC.
ONTREX, INC.
SK1452 Rev 3SK1452 Rev 3
SK1452 Rev 3SK1452 Rev 3
SK1452 Rev 3
Page 1
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - REQUIRED WIRING

ML-DRIVE INSTALLATION/START-UP GUIDECAUTIONHazardous Voltages. Can cause severe injury, death or damage toequipment. The ML-Drive should only be inst

Página 2

SCALINGAfter completing the required wiring of the ML-Drive, follow the procedure below to scale the ML-Drive for Masterformat RPM operation. Complet

Página 3 - TROUBLE-SHOOTING

FOLLOWER OPERATIONComplete the “Scaling” and “Tuning” procedures for Master mode (Page 2) before proceeding with Follower operation. To enable Follow

Página 4

Step 4: Check MP-47 (Drive Output).a) Should not be “0” or “100”.b) If “0”, then return to step 1 of “Scaling”.c) If “100”, check wiring to motor.