Contrex CX-1200 Manual do Utilizador Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 55
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
Page 16
F-Stop
(J6 pins 1, 3)
Digital Input 0
F-Stop is a momentary input. When it is opened, the
CX-1200 commands a zero speed immediately and
ignores the specified deceleration rate. However,
F-Stop does not hold zero speed or position (drive
disabled). As a momentary input, F-Stop is internally
latched and does not need to be maintained open by an
operator device.
R-Stop
(J6 pins 2, 3)
Digital Input 1
R-Stop is a momentary input. When it is opened, the
CX-1200 ramps to a zero speed command at the
specified deceleration rate. However, R-Stop does not
hold zero speed after the deceleration ramp has been
completed (drive disabled). As a momentary input, R-
Stop is internally latched and does not need to be
maintained open by an operator device.
H-Stop
(J6 pins 4, 3)
Digital Input 2
H-Stop is a momentary input. When it is opened, the
CX-1200 ramps to a zero speed command at the
specified deceleration rate. In addition, H-Stop holds
zero speed after the deceleration ramp has been
completed (drive enabled). As a momentary input,
H-Stop is internally latched and does not need to be
maintained open by an operator device.
Figure 15 F-Stop
F-STOP
1
3
J6
D
I_0
C
om
Figure 16 R-Stop
R-STOP
2
3
J6
D
I_1
C
om
H-STOP
3
4
J6
C
om
D
I_2
Figure 17 H-Stop
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 54 55

Comentários a estes Manuais

Sem comentários