Contrex M-Traverse Manual do Utilizador Página 70

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 69
3 - 23
Table 3-14 Default Control Parameters for Changes
CP Parameter Name Parameter Value
CP-24 Edge/Center Based 1
CP-25 Change Activation 1
CP-30 At-Home Band 4
CP-31 Home Offset 0
Table 3-15 Entering Control Parameters for Changes
CP Parameter Name Parameter Value
CP-24 Edge/Center Based Enter “1” for an edge based profile.
Enter “2” for a center based profile.
CP-25 Change Activation When CP-24 is set to “1” (edge based), then:
Enter “1” to activate changes when the Follower is in
the “Home position.
Enter “2” to activate changes immediately.
Enter “3” to activate changes when the Follower is in
the end dwell position.
CP-30 At-Home Band Enter the number of encoder lines that you want to
allow on either side of the “0” Home Set position.
CP-31 Home Offset If CP-24 is set at “1” (edge based), enter the distance
from the sensor to the desired position of “Home”.
If CP-24 is set at “2” (center based), enter the distance
from the sensor to the center of the web.